QL-DM70/40C Single-Station Sanding & Prep Booth (7 × 4 m)
Single-station sanding / prep booth, 7 × 4 m, rear-wall extraction with activated-carbon VOC filtration.
Versión en preparación: esta página se muestra en inglés por ahora.
Profix
Economy 7 × 4 m spray booth with Italian RIELLO-FS20 burner, fuel oil or gas heating optional.
| Heating method | fuel oil heating or gas heating |
|---|---|
| Outer dimensions (L×W×H) | 7000×4000×3300 mm |
| Inner dimensions (L×W×H) | 6900×3900×2650 mm |
| Plenum chamber | 380 mm |
| Floor base height | 270 mm |
| Voltage / frequency | 380 V / 50 Hz (customizable: 200 V/60 Hz, 440 V/60 Hz, 380 V/60 Hz) |
| Platform | mm Galvanized steel enclosure structure, 12 pieces of two‑course hot‑dip galvanized 30×5 mm steel gratings, three courses of 3 mm anti‑slip plates, electrostatic powder‑coated surface. The load‑bearing bracket adopts reinforced bent sheet‑metal frame structure. |
| Main door | 3000×2600 — Four‑leaf Hand‑built Sheet‑metal Main Doors Each door adopts 0.8 mm powder‑coated galvanized steel sheets for inner & outer panels, covered with protective films on both sides to avoid scratches. Door inner frame is welded with 1.2 mm galvanized keels. 6 mm cold‑rolled steel embedded plates are welded to keels at hinge locations to avoid door sagging. 180×120×15 mm aluminum‑alloy hinges provide high strength and nice appearance. Observation window: high‑temperature resistant rubber seal strips + 5 mm rounded tempered glass for safety.18 kg fire‑retardant filler is bonded inside the door to ensure panel flatness. |
| Emergency exit door | 680*2000 — mm thick aluminum alloy edge wrapping ensures good sealing and anti‑deformation performance. |
| Wall material | mm rock wool sandwich panel with 0.426 mm double‑sided steel sheets and 100 kg/m³ rock‑wool density.Side reinforcing keels avoid tearing during loading & unloading and enhance wind‑pressure resistance.Inner‑outer protective films reduce surface scratches. |
| Roof panel | mm Galvanized bent top panel, steel sheet thickness: 0.8 mm |
| Floor slope | three options available: inner‑side 1m slope, outer‑side 1m slope, full outer‑side slope. |
| Supply fan | h Equipped with 2 sets of YDW‑series centrifugal fans from Yancheng Hengkang, each rated at 4 kW. Total air volume: 24000 m³/h, total pressure: 800 Pa. Side upper air intake. Average loaded air velocity: 0.3‑0.35 m/s; Air‑change rate: 238 times/h. |
| Exhaust fan | Optional |
| Heating system | double‑layer stainless steel heat exchanger, pneumatic damper actuator for spray‑to‑bake cycle. Max thermal efficiency: 260000 kcal/h, maximum set temperature: 80℃, 4 chimneys and 1 elbow. |
| Control system | Assembled with high‑quality electronic components. Multiple protections are equipped in the main circuit. It is provided with lighting switch, spray mode, constant‑temperature spray mode, baking temperature & time setting, emergency‑stop indicator light, fault alarm and other functions. |
| Air filtration | One layer of high‑quality intake filter cotton, effectively filters dust particles larger than 10 μm. Top filter adopts CC‑600G sub‑high‑efficiency filter cotton, effectively filters dust particles larger than 5 μm. TSP value: ≤1.4 mg/m³. |
| Exhaust treatment | Optional |
| Exhaust duct | 700*700*910 — three straight sections plus one elbow, dimension 700×700×910 mm, machine‑formed from 0.8 mm galvanized steel sheet. |
QL-R70/40C — The QL-R70/40C is the economy model of the fuel-heated series: an Italian RIELLO burner with double-layer stainless-steel heat exchanger heats the circulating air, suitable for workshops with diesel or gas supply. Inner dimensions 6900×3900×2650 mm, outer 7000×4000×3300 mm.
Heating: double‑layer stainless steel heat exchanger, pneumatic damper actuator for spray‑to‑bake cycle. Max thermal efficiency: 260000 kcal/h, maximum set temperature: 80℃, 4 chimneys and…. Air side: Equipped with 2 sets of YDW‑series centrifugal fans from Yancheng Hengkang, each rated at 4 kW. Total air volume: 24000 m³/h, total pressure: 800 Pa. Side upper air intake.….
Structure: 50 mm rock-wool sandwich panels (100 kg/m³), four hand-built sheet-metal main doors 3000×2600 mm with tempered-glass observation windows, one aluminium-edged emergency exit door, galvanized raised floor with steel gratings (slope options available). Control: Delixi mechanical control cabinet with independent breakers, temperature/time setting and emergency stop. Intake filtration: Intake filter cotton + CC-600G ceiling filters. TSP value ≤ 1.4 mg/m³. Exhaust-gas treatment (activated-carbon cabinet or photocatalytic unit) is available as an option.
Voltage 380 V/50 Hz as standard; 200 V/60 Hz, 440 V/60 Hz and 380 V/60 Hz available on request. Sea freight, SKD packed; contact us for a quotation.