QL-DM70/40C Single-Station Sanding & Prep Booth (7 × 4 m)
Single-station sanding / prep booth, 7 × 4 m, rear-wall extraction with activated-carbon VOC filtration.
Versión en preparación: esta página se muestra en inglés por ahora.
Profix
Premium enlarged 7.5 × 4.5 m spray booth with centralized electric heating, PLC and QL-XF10K carbon cabinet.
| Heating method | Centralized electric heating |
|---|---|
| Outer dimensions (L×W×H) | 7600×4600×3500 mm |
| Inner dimensions (L×W×H) | 7500×4500×2800 mm |
| Plenum chamber | 400 mm |
| Floor base height | 270 mm |
| Voltage / frequency | 380 V / 50 Hz (customizable: 200 V/60 Hz, 440 V/60 Hz, 380 V/60 Hz) |
| Platform | Stainless steel enclosure structure. 12 pcs of two‑row hot‑dip galvanized 30×5 mm steel gratings, three rows of 3 mm anti‑slip plates with electrostatic powder‑coated surfaces. Stainless steel square tubes are used as support legs, with 6 longitudinal supports arranged. |
| Main door | 3000×2600 — four‑leaf hand‑fabricated sheet‑metal main doors. Each door’s inner and outer panels are hand‑made of 0.8 mm powder‑coated galvanized steel sheets, with protective films on both sides to reduce surface scratches. 1.2 mm galvanized keels are spliced and welded around the interior of each door. 6 mm cold‑rolled steel plates are pre‑embedded and welded to the keels at hinge mounting positions to prevent door sagging. 180×120, 15 mm thick aluminum‑alloy hinges are adopted for high mechanical strength and elegant appearance. The observation window is fitted with high‑temperature rubber inner sealing strips and 5 mm tempered round glass for personnel safety. 18 kg flame‑retardant filler is bonded inside the door with panels to ensure overall flatness. |
| Emergency exit door | 680*2000 — mm thick aluminum alloy edge wrapping ensures good sealing and anti‑deformation performance. |
| Wall material | mm rock wool sandwich panel with 0.426 mm double‑sided steel sheets and 100 kg/m³ rock‑wool density.Side reinforcing keels avoid tearing during loading & unloading and enhance wind‑pressure resistance.Inner‑outer protective films reduce surface scratches. |
| Roof panel | mm rock wool panel, double‑sided 0.426 mm steel sheet, rock wool density: 100 kg/m³. |
| Floor slope | three options available: inner‑side 1m slope, outer‑side 1m slope, full outer‑side slope. |
| Supply fan | h Equipped with one Yancheng Hengkang DDF series single‑inlet centrifugal fan, Model 630B, 7.5 kW variable‑frequency motor. Air volume: 28000‑30000 m³/h, total pressure: 600 Pa. Side‑top air intake, loaded wind speed: 0.38‑0.45 m/s; air change rate: 330 times/h. |
| Exhaust fan | pa Equipped with 1 unit of 4‑82‑6.3E 15 kW turbo exhaust fan, air volume: 38525 m³/h, total pressure: 1465‑986 Pa. |
| Heating system | mm Heated by centralized 304 stainless steel fin‑type electric heating tubes, consisting of modified magnesium oxide powder, high‑resistance electric heating alloy wires, ceramic insulated terminals and stainless steel cooling fins. Fins wrapped around tube surfaces for air heat exchange, rust‑proof and high‑temperature resistant. 12 heating tubes, 5 kW each; total 60 kW. 20‑min heat‑up time to 60℃ baking temperature, max set temperature 80℃. Supports heating‑up spraying, with circulating damper for spray‑bake cycle. Independent heater cabinet mounted on supply fan cabinet, frame welded from 50×50×1.4 mm formed profiles with powder‑coated surface, covered with 20 mm high‑strength sound‑absorbing machine‑made rock wool panels. Wiring area is externally separated from heat exchange zone; silicone‑mica braided high‑temperature wires adopted with star‑connection wiring. Adopt upper‑damper heating for fire safety of baking booth, preventing paint residue on floor filters and gratings from being blown onto heating tubes to avoid fire hazards and guarantee heater heat‑exchange efficiency. |
| Control system | Mechanical‑type control cabinet with Delixi (China well‑known brand) electrical components. Independent circuit breakers for main control, fans and lighting. Fitted with lighting switch, spray switch and working indicators. Supports heating‑up spray mode, baking temperature adjustment, time setting and emergency stop. Each two groups of heating lamps have separate control. Fans are equipped with thermal overload protection. |
| Air filtration | bag filter cotton, effectively filters dust particles larger than 10 μm. Top filter: CC‑600G sub‑high‑efficiency filter cotton, effectively filters dust particles larger than 5 μm. TSP value: ≤1.4 mg/m³. |
| Exhaust treatment | pa Activated carbon adsorption method, cabinet dimensions: L1600×W1250×H2500 mm (motor excluded). Two‑stage primary plate filter cotton for pre‑treatment, 6‑layer honeycomb activated carbon with iodine value ≥600, approx. 1 m³. Equipped with 1 unit of 4‑82‑6.3E 15 kW turbo exhaust fan, air volume: 38525 m³/h, total pressure: 1465‑986 Pa. |
| Exhaust duct | 700*700*910 — three straight sections plus one elbow, dimension 700×700×910 mm, machine‑formed from 0.8 mm galvanized steel sheet. |
| Negative-pressure safety device | To prevent excessive indoor negative pressure under special conditions, the air suction panel opens automatically to reduce indoor negative pressure and e nsure chamber safety. |
QL-DJ75/45/28A + QL-XF10K — The QL-DJ/S350 is the premium centralized electric heating model, combining centralized hot-air heating with PLC + touchscreen control, inverter fan and internal circulation during baking. Inner dimensions 7500×4500×2800 mm, outer 7600×4600×3500 mm.
Heating: Heated by centralized 304 stainless steel fin‑type electric heating tubes, consisting of modified magnesium oxide powder, high‑resistance electric heating alloy wires, ceramic…. Air side: Equipped with one Yancheng Hengkang DDF series single‑inlet centrifugal fan, Model 630B, 7.5 kW variable‑frequency motor. Air volume: 28000‑30000 m³/h, total pressure: 600 Pa.… Exhaust: Equipped with 1 unit of 4‑82‑6.3E 15 kW turbo exhaust fan, air volume: 38525 m³/h, total pressure: 1465‑986 Pa..
Structure: 50 mm rock-wool sandwich panels (100 kg/m³), four hand-built sheet-metal main doors 3000×2600 mm with tempered-glass observation windows, one aluminium-edged emergency exit door, galvanized raised floor with steel gratings (slope options available). Control: Delixi mechanical control cabinet with independent breakers, temperature/time setting and emergency stop. Intake filtration: Intake filter cotton + CC-600G ceiling filters. TSP value ≤ 1.4 mg/m³. Exhaust-gas treatment (activated-carbon cabinet or photocatalytic unit) is available as an option.
Voltage 380 V/50 Hz as standard; 200 V/60 Hz, 440 V/60 Hz and 380 V/60 Hz available on request. Sea freight, SKD packed; contact us for a quotation.
Single-station sanding / prep booth, 7 × 4 m, rear-wall extraction with activated-carbon VOC filtration.
Two-station sanding / prep booth sharing one 5.5 kW exhaust system — saves floor space and equipment cost.
Three-station sanding / prep booth, 7 × 12 m, shared extraction with activated-carbon VOC filtration.