QL-DM70/40C Single-Station Sanding & Prep Booth (7 × 4 m)
Single-station sanding / prep booth, 7 × 4 m, rear-wall extraction with activated-carbon VOC filtration.
Version française en préparation — cette page s'affiche pour l'instant en anglais.
Profix
Economy 7 × 4 m spray booth with 30 kW short-wave halogen infrared heating mounted beside double doors.
| Heating method | Short‑wave Halogen Infrared Electric Heating (Double‑door, External‑mounted) |
|---|---|
| Outer dimensions (L×W×H) | 7000×4000×3300 mm |
| Inner dimensions (L×W×H) | 6900×3900×2650 mm |
| Plenum chamber | 380 mm |
| Floor base height | 270 mm |
| Voltage / frequency | 380 V / 50 Hz (customizable: 200 V/60 Hz, 440 V/60 Hz, 380 V/60 Hz) |
| Platform | mm Galvanized steel enclosure structure, 12 pieces of two‑course hot‑dip galvanized 30×5 mm steel gratings, three courses of 3 mm anti‑slip plates, electrostatic powder‑coated surface. The load‑bearing bracket adopts reinforced bent sheet‑metal frame structure. |
| Main door | 3000×2600 — Four‑leaf Hand‑built Sheet‑metal Main Doors Each door adopts 0.8 mm powder‑coated galvanized steel sheets for inner & outer panels, covered with protective films on both sides to avoid scratches. Door inner frame is welded with 1.2 mm galvanized keels. 6 mm cold‑rolled steel embedded plates are welded to keels at hinge locations to avoid door sagging. 180×120×15 mm aluminum‑alloy hinges provide high strength and nice appearance. Observation window: high‑temperature resistant rubber seal strips + 5 mm rounded tempered glass for safety.18 kg fire‑retardant filler is bonded inside the door to ensure panel flatness. |
| Emergency exit door | 680*2000 — mm thick aluminum alloy edge wrapping ensures good sealing and anti‑deformation performance. |
| Wall material | mm rock wool sandwich panel with 0.426 mm double‑sided steel sheets and 100 kg/m³ rock‑wool density.Side reinforcing keels avoid tearing during loading & unloading and enhance wind‑pressure resistance.Inner‑outer protective films reduce surface scratches. |
| Roof panel | mm Galvanized bent top panel, steel sheet thickness: 0.8 mm |
| Floor slope | three options available: inner‑side 1m slope, outer‑side 1m slope, full outer‑side slope. |
| Supply fan | h Equipped with 2 sets of YDW‑series centrifugal fans from Yancheng Hengkang, each rated at 4 kW. Total air volume: 24000 m³/h, total pressure: 800 Pa. Side upper air intake. Average loaded air velocity: 0.3‑0.35 m/s; Air‑change rate: 238 times/h. |
| Exhaust fan | Optional |
| Heating system | Heating adopts short‑wave gold‑plated halogen infrared radiant lamps. 10 groups of heaters, 3 lamps per group, 1.0 kW per lamp, total power 30 kW. External mounting beside double‑door.Heater power supply: 2.5 mm² 500 °C high‑temperature cables, laid in 40×80 steel cable trays. |
| Control system | Mechanical‑type control cabinet with Delixi (China well‑known brand) electrical components. Independent circuit breakers for main control, fans and lighting. Fitted with lighting switch, spray switch and working indicators. Supports heating‑up spray mode, baking temperature adjustment, time setting and emergency stop. Each two groups of heating lamps have separate control. Fans are equipped with thermal overload protection. |
| Air filtration | One layer of high‑quality intake filter cotton, effectively filters dust particles larger than 10 μm. Top filter adopts CC‑600G sub‑high‑efficiency filter cotton, effectively filters dust particles larger than 5 μm. TSP value: ≤1.4 mg/m³. |
| Exhaust treatment | Optional |
| Exhaust duct | 700*700*910 — three straight sections plus one elbow, dimension 700×700×910 mm, machine‑formed from 0.8 mm galvanized steel sheet. |
QL-D70/40C — The QL-D70/40C is the economy model of the distributed electric heating series: short-wave halogen infrared lamp tubes mounted externally beside the double doors deliver radiant heat directly to the paint surface, while two centrifugal supply fans keep the booth at a slight positive pressure. Inner dimensions 6900×3900×2650 mm, outer 7000×4000×3300 mm.
Heating: Heating adopts short‑wave gold‑plated halogen infrared radiant lamps. 10 groups of heaters, 3 lamps per group, 1.0 kW per lamp, total power 30 kW. External mounting beside…. Air side: Equipped with 2 sets of YDW‑series centrifugal fans from Yancheng Hengkang, each rated at 4 kW. Total air volume: 24000 m³/h, total pressure: 800 Pa. Side upper air intake.….
Structure: 50 mm rock-wool sandwich panels (100 kg/m³), four hand-built sheet-metal main doors 3000×2600 mm with tempered-glass observation windows, one aluminium-edged emergency exit door, galvanized raised floor with steel gratings (slope options available). Control: Delixi mechanical control cabinet with independent breakers, temperature/time setting and emergency stop. Intake filtration: Intake filter cotton + CC-600G ceiling filters. TSP value ≤ 1.4 mg/m³. Exhaust-gas treatment (activated-carbon cabinet or photocatalytic unit) is available as an option.
Voltage 380 V/50 Hz as standard; 200 V/60 Hz, 440 V/60 Hz and 380 V/60 Hz available on request. Sea freight, SKD packed; contact us for a quotation.
Single-station sanding / prep booth, 7 × 4 m, rear-wall extraction with activated-carbon VOC filtration.
Two-station sanding / prep booth sharing one 5.5 kW exhaust system — saves floor space and equipment cost.
Three-station sanding / prep booth, 7 × 12 m, shared extraction with activated-carbon VOC filtration.